5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Mounting Surface To Terminal End Distance

    1.700 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Position Designation

    at pole one

  • Nominal Thread Size

    0.375 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.055 minimum at 200 pct and 0.950 maximum at 200 pct and 0.240 maximum at 400 pct single location

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Switch Terminal Type

    tab, solder lug

  • Definitive Government Spec/Std Reference

    m39019-2-41

  • Test Data Document

    81349-mil-c-39019 specification

  • Thread Series Designator

    unef

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc single location

  • Trip Release Method

    magnetic single location

  • Ultimate Trip Time Per Pole In Seconds

    0.200 minimum and 0.700 maximum single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Internal Trip Release Configuration

    series trip single location

  • Switch Location And Position Designation

    internal at pole one

  • Switch Current Rating And Type In Amps

    0.5 ac and 0.5 dc

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 50.0 dc

  • Manufacturers Code

    81349

  • Non-Definitive Government Spec/Std Reference

    milc39019-2

  • Terminal Type And Quantity

    2 wire hook

  • Thread Pitch Diameters

    0.3503 to 0.3537 inches

  • Body Style

    2a single pole type

  • Bushing Length

    0.280 inches minimum and 0.380 inches maximum

  • Body Length

    1.562 inches maximum

  • Body Width

    0.625 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Pole Quantity

    1

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...