112-507-101

Circuit Breakers

CIRCUIT BREAKER

112-507-101

5925-00-458-6641

5925 - Circuit Breakers

Wood Electric Operations Potter And

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Arc Quenching Method

    air

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Fragility Factor

    moderately rugged

  • Trip Delay Time In Seconds Per Rated Continuous Current

    6.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location

  • Maximum Continuous Load Current Rating Per Pole

    7.5 amperes ac single location and 7.5 amperes dc single location

  • Inclosure Protection Type For Which Designed

    salt spray proof and humidity proof and shockproof and vibrationproof

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Center To Center Distance Between Terminals Parallel To Length

    1.120 inches nominal

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Body Length

    1.375 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 single location

  • Mounting Surface To Terminal End Distance

    2.035 inches nominal

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Body Width

    0.690 inches nominal

  • Bushing Length

    0.335 inches nominal

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location and 2500.0 dc single location

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Terminal Type And Quantity

    2 tab w/screw

  • Unpackaged Unit Weight

    2.000 ounces

  • Nominal Thread Size

    0.469 inches

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location and 50.0 dc single location

  • Thread Series Designator

    uns

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...