580R661H02
Switches
SWITCH,THERMOSTATIC
580R661H02
Northrop Grumman Systems Corporation
SWITCH,THERMOSTATIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Contact Action Stimulus
increase
-
Contact Voltage Rating In Volts
28.0 dc at sea level third voltage
-
Contact Adjustability
deactuation point not adjustable and actuation point not adjustable
-
Frequency In Hertz
400.0 single voltage
-
Contact Load Current Rating
5.0 amperes resistive load third voltage
-
Contact Voltage Rating In Volts
115.0 ac at sea level second voltage
-
Nonpile-Up Contact Arrangement
1 pole, single throw, normally closed, momentary action
-
Media For Which Designed
gas or liquid
-
Contact Load Current Rating
1.0 amperes resistive load first voltage
-
Body Diameter
0.640 inches nominal
-
Temp Sensing Element Type
internal sensor
-
Contact Load Current Rating
2.0 amperes resistive load second voltage
-
Overall Height
0.320 inches maximum
-
Terminal Type
tab, solder lug
-
Overall Length
0.690 inches nominal
-
Mounting Method
clamp
-
Style Designator
disc
-
Contact Voltage Rating In Volts
250.0 ac at sea level first voltage
-
Operating Temp Rating
125.0 deg celsius maximum and -65.0 deg celsius minimum
-
~1
degrees fahrenheit
-
Contact Stimulus Rating
171.00 actuation point maximum degrees fahrenheit and 161.00 actuation point minimum degrees fahrenheit and 166.00 deactuation point maximum degrees fahrenheit and 160.00 deactuation point minimum degrees fahrenheit and 3.00 differential point nominal