K3051

Circuit Breakers

CIRCUIT BREAKER

K3051

5925-00-462-2328

5925 - Circuit Breakers

Technology Dynamics Inc.

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Nominal Thread Size

    0.138 inches

  • Frequency In Hertz

    60.0 all locations

  • Body Length

    5.768 inches minimum and 5.832 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Body Height

    2.577 inches minimum and 2.641 inches maximum

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Boss Height

    0.187 inches minimum and 0.251 inches maximum

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Body Width

    2.020 inches minimum and 2.084 inches maximum

  • Terminal Type And Quantity

    4 compression

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac all locations

  • Fragility Factor

    moderately rugged

  • Circuit Protection Type

    overcurrent all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    39.000 minimum at 200 pct all locations and 100.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    dustproof

  • Pole Quantity

    2

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    35.0 amperes ac second location

  • Trip Release Duty Cycle

    continuous all locations

  • Manual Actuator Type And Quantity

    2 toggle

  • Operating Voltage Type And Rating Per Pole In Volts

    220.0 ac first location

  • Center To Center Distance Between Terminals Parallel To Width

    0.994 inches minimum and 1.058 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    17.5 amperes ac first location

  • External Actuator Linkage Arrangement

    one and two linked

  • Operating Voltage Type And Rating Per Pole In Volts

    440.0 ac second location

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...