Technical Characteristics

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    2 toggle

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one and two linked

  • Unpackaged Unit Weight

    8.000 ounces

  • Terminal Type And Quantity

    4 threaded stud

  • Body Style

    multipole-multiple actuator type

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

  • Body Width

    1.490 inches minimum and 1.510 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    2.645 inches maximum

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes dc

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc

  • Trip Release Method

    thermal

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Boss Height

    0.090 inches minimum and 0.165 inches maximum

  • Pole Quantity

    2

  • Storage Type

    general purpose warehouse

  • Circuit Protection Type

    overcurrent

  • Actuator Position Designation

    at each pole

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.500 minimum at 200 pct and 7.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    explosion proof and shockproof

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal

  • Thread Series Designator

    unc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...