171-105-4MG6
Circuit Breakers
CIRCUIT BREAKER
171-105-4MG6
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Width
3.797 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.060 inches nominal
-
Switch Contact Arrangement
single pole, double throw
-
Boss Height
0.140 inches nominal
-
Mounting Surface To Terminal End Distance
2.841 inches nominal
-
Maximum Continuous Load Current Rating Per Pole
6.0 amperes dc fourth location
-
Maximum Continuous Load Current Rating Per Pole
6.0 amperes dc third location
-
Maximum Continuous Load Current Rating Per Pole
7.0 amperes dc first location
-
Maximum Continuous Load Current Rating Per Pole
7.0 amperes dc second location
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc first location
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc second location
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc third location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc all locations
-
Circuit Protection Type
overcurrent all locations
-
Trip Release Method
magnetic-hydraulic all locations
-
Trip Release Characteristic
time delay first location
-
Trip Release Characteristic
time delay fourth location
-
Trip Release Characteristic
time delay third location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
5 toggle
-
Actuator Function
trip-reset
-
Actuator Position Designation
at each pole
-
Auxiliary Switch Function And Quantity
4 alarm
-
Nominal Thread Size
0.138 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.180 minimum at 200 pct third location and 0.550 maximum at 200 pct
-
Body Style
8c multipole-multiple actuator type
-
Body Length
2.500 inches nominal
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Length
1.940 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Pole Quantity
5
-
Mounting Facility Type And Quantity
10 threaded hole
-
Storage Type
general purpose warehouse
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes dc fifth location
-
Operating Voltage Type And Rating Per Pole In Volts
40.0 dc fifth location
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc fourth location
-
Trip Release Characteristic
instantaneous fifth location
-
Trip Release Characteristic
time delay second location
-
External Actuator Linkage Arrangement
one, two, three, four, and five linked
-
Internal Trip Release Configuration
series trip all locations
-
Switch Location And Position Designation
internal at each pole
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Switch Terminal Type
tab, solder lug
-
Switch Current Rating And Type In Amps
2.5 ac and 1.0 dc
-
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
-
Thread Series Designator
unc
-
Terminal Type And Quantity
10 threaded stud