150-0741

Circuit Breakers

CIRCUIT BREAKER

150-0741

5925-00-465-2259

5925 - Circuit Breakers

Continental Electronics Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Auxiliary Switch Function And Quantity

    1 control

  • Body Style

    multipole-multiple actuator type

  • Body Length

    4.750 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    3.550 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.026 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Mounting Surface To Terminal End Distance

    3.484 inches nominal

  • Circuit Protection Type

    overcurrent

  • Trip Release Method

    magnetic

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Time Per Pole In Seconds

    600.000 nominal

  • Reset Method

    manual

  • External Actuator Linkage Arrangement

    one and two linked

  • Switch Location And Position Designation

    internal at pole one

  • Switch Terminal Type

    wire hook

  • Terminal Type And Quantity

    4 threaded stud

  • Body Width

    2.052 inches nominal

  • Switch Contact Arrangement

    single pole,double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.026 inches nominal

  • Boss Height

    0.250 inches nominal

  • Pole Quantity

    2

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    2 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    130.000 minimum at 125 pct and 600.000 maximum at 125 pct

  • Frequency In Hertz

    60.0

  • Thread Series Designator

    unc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.