CD3-A2A3A3-AB-12-480-3

Circuit Breakers

CIRCUIT BREAKER

CD3-A2A3A3-AB-12-480-3

5925-00-465-2267

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Width

    1.026 inches nominal

  • Precious Material

    silver

  • Storage Type

    general purpose warehouse

  • Switch Current Rating And Type In Amps

    5.0 ac and 1.0 dc

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 50.0 dc

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.026 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac single location

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Switch Contact Arrangement

    single pole, double throw

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Manual Actuator Type And Quantity

    3 toggle

  • Unpackaged Unit Weight

    2.000 pounds

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct all locations and 0.600 maximum at 200 pct all locations

  • Mounting Facility Type And Quantity

    4 threaded hole and 2 slot

  • Body Width

    2.052 inches nominal

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 threaded stud

  • Switch Location And Position Designation

    internal at pole one and internal at pole three

  • Nominal Thread Size

    0.138 inches

  • Maximum Continuous Load Current Rating Per Pole

    12.0 amperes ac all locations

  • Frequency In Hertz

    60.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Center To Center Distance Between Terminals Parallel To Length

    3.550 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Precious Material And Location

    contact surfaces silver

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Mounting Surface To Terminal End Distance

    4.000 inches nominal

  • Boss Height

    0.219 inches nominal

  • Body Length

    4.750 inches nominal

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Mounting Slot Width

    0.164 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...