M55629/6-038
Circuit Breakers
CIRCUIT BREAKER
M55629/6-038
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Switch Contact Arrangement
single pole,double throw
-
Fragility Factor
moderately rugged
-
Boss Height
0.109 inches minimum and 0.171 inches maximum
-
Mounting Surface To Terminal End Distance
2.800 inches maximum
-
Pole Quantity
3
-
Mounting Facility Type And Quantity
6 threaded hole
-
Thread Quantity Per Inch
32
-
Trip Release Characteristic
time delay
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
-
Reset Method
manual
-
Manual Actuator Type And Quantity
3 toggle
-
Actuator Function
trip-reset
-
Actuator Position Designation
at each pole
-
External Actuator Linkage Arrangement
one,two,and three linked
-
Auxiliary Switch Function And Quantity
1 alarm
-
Nominal Thread Size
0.138 inches
-
Switch Location And Position Designation
internal at pole two
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.200 minimum at 200 pct and 20.000 maximum at 200 pct
-
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
-
Frequency In Hertz
60.0
-
Test Data Document
81349-mil-c-55629 specification
-
Specification/Standard Data
81349-mil-c-55629/6 government specification
-
Body Length
2.510 inches maximum
-
Body Width
2.156 inches minimum and 2.344 inches maximum
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Length
1.660 inches minimum and 1.960 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
0.719 inches minimum and 0.781 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.046 inches minimum and 2.078 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.719 inches minimum and 0.781 inches maximum
-
Arc Quenching Method
magnetic blowout
-
Storage Type
general purpose warehouse
-
Maximum Continuous Load Current Rating Per Pole
4.0 amperes ac
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac
-
Circuit Protection Type
overcurrent
-
Trip Release Method
magnetic
-
Main Contact Tripping Mechanism Type
trip free
-
Internal Trip Release Configuration
series trip
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Switch Terminal Type
tab,solder lug
-
Switch Current Rating And Type In Amps
10.0 ac and 2.0 dc
-
Thread Series Designator
unc
-
Terminal Type And Quantity
6 threaded stud