561109
Coils and Transformers
TRANSFORMER,POWER
561109
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Thread Series Designator
unc single group
-
Winding Operating Voltage
440.00 ac volts nominal single component single primary
-
Thread Direction (Non-Core)
err-070
-
Cubic Measure (Non-Core)
34.2 cubic inches
-
Mounting Facility Quantity
4 single group
-
Body Width
2.500 inches minimum and 2.625 inches maximum
-
Winding Shielding Method
internal shield grounded to inclosure and core single component
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.843 inches minimum single mounting facility single center group and 1.859 inches maximum single mounting facility single center group
-
Nominal Thread Size
0.164 inches single group
-
Mounting Method
threaded stud single group
-
Body Height
4.125 inches minimum and 4.250 inches maximum
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Body Length
2.937 inches minimum and 3.062 inches maximum
-
Winding Operating Voltage
25.00 ac volts nominal single component single secondary
-
Terminal Type And Quantity
4 solder stud
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.281 inches minimum single mounting facility single center group and 2.297 inches maximum single mounting facility single center group
-
Reliability Indicator
not established
-
Frequency Rating
400.0 hertz nominal single component
-
Winding Operating Current
10.0 amperes ac maximum single component single secondary
-
Input-Output Phase Relationship
single phase to single phase single component
-
Maximum Operating Temp
130.0 deg celsius
-
Inclosure Type
hermetically sealed