371D957G18

Circuit Breakers

CIRCUIT BREAKER

371D957G18

5925-00-471-1898

5925 - Circuit Breakers

Eaton Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Inclosure Protection Type For Which Designed

    general purpose

  • Body Height

    4.057 inches minimum and 4.067 inches maximum

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Main Contact Tripping Mechanism Type

    trip free

  • Center To Center Distance Between Terminals Parallel To Length

    8.432 inches minimum and 8.442 inches maximum

  • Manual Actuator Type And Quantity

    1 toggle

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Body Style

    multipole-single actuator type

  • Unthreaded Mounting Hole Diameter

    0.500 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    3.432 inches minimum and 3.442 inches maximum

  • Actuator Position Designation

    at pole two

  • Trip Release Method

    thermal-magnetic all locations

  • Terminal Type And Quantity

    6 clip

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Storage Type

    general purpose warehouse

  • Features Provided

    adjustable trip release

  • Reset Method

    manual

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Special Handling Feature

    magnetic

  • Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    8.870 inches minimum and 8.880 inches maximum

  • Frequency In Hertz

    400.0 all locations

  • Adjustable Trip Setting Current Range Per Pole In Amps

    +6000.0/+13000.0 ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.713 inches minimum and 1.723 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    14000.0 ac all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    195.000 minimum at 200 pct all locations and 600.000 maximum at 200 pct all locations

  • Case Material

    plastic

  • Boss Height

    0.495 inches minimum and 0.505 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations

  • Body Length

    10.120 inches minimum and 10.130 inches maximum

  • Body Width

    5.495 inches minimum and 5.505 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    200.0 amperes ac all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...