Technical Characteristics

  • Terminal Type And Quantity

    2 wire hook

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Center To Center Distance Between Terminals Parallel To Length

    0.687 inches nominal

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Ultimate Trip Time Per Pole In Seconds

    0.035 nominal single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Switch Contact Arrangement

    single pole, double throw

  • Pole Quantity

    1

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Switch Location And Position Designation

    external at pole one

  • Trip Release Method

    thermal-magnetic single location

  • Thread Series Designator

    unef

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 50.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc single location

  • Body Style

    single pole type

  • Switch Terminal Type

    eyelet

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Body Length

    1.750 inches maximum

  • Trip Release Characteristic

    instantaneous single location

  • Mounting Surface To Terminal End Distance

    1.635 inches nominal

  • Inclosure Protection Type For Which Designed

    shockproof and vibrationproof and hermetically sealed

  • Bushing Length

    0.315 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    1.5 amperes dc single location

  • Switch Current Rating And Type In Amps

    1.0 ac and 0.5 dc

  • Body Width

    0.625 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...