CD3-A2A3A3-AB-2-480-3

Circuit Breakers

CIRCUIT BREAKER

CD3-A2A3A3-AB-2-480-3

5925-00-479-3811

5925 - Circuit Breakers

Essex Substance Abuse Treatment

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac all locations

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Body Width

    3.093 inches maximum

  • Cubic Measure

    63.406 cubic inches

  • Manual Actuator Type And Quantity

    3 toggle

  • Switch Voltage Rating And Type In Volts

    1215.0 ac and 50.0 dc

  • Unpackaged Unit Weight

    2.000 pounds

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 threaded stud

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Precious Material

    silver

  • Storage Type

    general purpose warehouse

  • Switch Current Rating And Type In Amps

    5.0 ac and 1.0 dc

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    6 threaded bushing w/panel seal

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Switch Contact Arrangement

    single pole, double throw

  • Special Features

    voltage protection barriers between poles

  • Nominal Thread Size

    0.138 inches

  • Inclosure Protection Type For Which Designed

    fungus resistant and humidity resistant

  • Main Contact Tripping Mechanism Type

    trip free

  • Center To Center Distance Between Terminals Parallel To Length

    3.550 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    2.052 inches nominal

  • Precious Material And Location

    contact surfaces silver

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Mounting Surface To Terminal End Distance

    4.000 inches nominal

  • Boss Height

    0.219 inches nominal

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Center To Center Distance Between Terminals Parallel To Width

    2.052 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.350 minimum at 200 pct all locations and 1.000 maximum at 200 pct all locations

  • Body Length

    4.750 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...