7851-18-50

Circuit Breakers

CIRCUIT BREAKER

7851-18-50

5925-00-479-7153

5925 - Circuit Breakers

Cessna Aircraft Company

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac single location and 25.0 amperes dc single location

  • Storage Type

    general purpose warehouse

  • Body Width

    1.250 inches nominal

  • Manual Actuator Type And Quantity

    1 push button

  • Terminal Type And Quantity

    2 screw

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Mounting Surface To Terminal End Distance

    1.266 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    7.000 nominal at 200 pct single location and 1.450 nominal at 300 pct single location

  • Pole Quantity

    1

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.574 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    600.0 ac single location and 600.0 dc single location

  • Internal Trip Release Configuration

    series trip single location

  • Operating Voltage Type And Rating Per Pole In Volts

    125.0 ac single location and 30.0 dc single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Actuator Function

    reset

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    130.0 single location

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Main Contact Tripping Mechanism Type

    trip free

  • Nominal Thread Size

    0.164 inches

  • Body Style

    single pole type

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches nominal

  • Frequency In Hertz

    60.0 single location

  • Trip Release Characteristic

    instantaneous single location and time delay single location

  • Inclosure Protection Type For Which Designed

    dustproof and fungus resistant

  • Overall Length

    2.000 inches nominal

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...