4MC1-203-0.05

Circuit Breakers

CIRCUIT BREAKER

4MC1-203-0.05

5925-00-479-7909

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Ultimate Trip Time Per Pole In Seconds

    7.000 minimum and 50.000 maximum single location

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Switch Location And Position Designation

    internal at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.500 minimum at 200 pct and 10.000 maximum at 200 pct single location

  • Switch Terminal Type

    tab, solder lug

  • Terminal Type And Quantity

    2 threaded stud

  • Nominal Thread Size

    0.138 inches

  • Inclosure Protection Type For Which Designed

    explosion resistant and fungus resistant and moisture resistant

  • Switch Current Rating And Type In Amps

    5.0 ac and 1.0 dc

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 50.0 dc

  • Frequency In Hertz

    400.0 single location

  • Thread Series Designator

    unc

  • Body Length

    2.500 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Boss Height

    0.140 inches nominal

  • Mounting Surface To Terminal End Distance

    2.611 inches nominal

  • Iii Arc Quenching Method

    air

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Iii Storage Type

    general purpose warehouse

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Characteristic

    time delay single location

  • Thread Pitch Diameters

    0.1177 to 0.1214 inches

  • Body Style

    12a single pole type

  • Body Width

    0.750 inches nominal

  • Switch Contact Arrangement

    single pole, double throw

  • Iii Fragility Factor

    moderately rugged

  • Pole Quantity

    1

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    50.0 milliamperes ac single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Internal Trip Release Configuration

    series trip single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...