10915

Coils and Transformers

TRANSFORMER,POWER

10915

5950-00-481-8231

5950 - Coils and Transformers

Pulse Electronics

TRANSFORMER,POWER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Frequency Rating

    47.0 hertz minimum single component and 420.0 hertz maximum

  • Input-Output Phase Relationship

    single phase to single phase single component

  • Winding Shielding Method

    internal shield brought out to terminal single component

  • Mounting Facility Quantity

    4 single group

  • Mounting Method

    threaded hole single group

  • Winding Function And Quantity

    1 primary single component and 2 secondary

  • Winding Operating Current

    400.0 milliamperes ac maximum single component 1st secondary

  • Nominal Thread Size

    0.138 inches single group

  • Winding Tap Location

    center tap single component 1st secondary

  • Winding Tap Location

    tap w/o center tap single component single primary

  • Winding Operating Current

    4.0 amperes ac maximum single component 2nd secondary

  • Thread Series Designator

    unc single group

  • Terminal Type And Quantity

    9 tab, solder lug

  • Center To Center Distance Between Mounting Facilities Parallel To Length

    3.250 inches nominal single mounting facility single center group

  • Thread Class

    2b single group

  • Thread Direction

    right-hand single group

  • Reliability Indicator

    not established

  • Center To Center Distance Between Mounting Facilities Parallel To Width

    3.000 inches nominal single mounting facility single center group

  • Body Length

    4.250 inches maximum

  • Body Width

    3.750 inches maximum

  • Body Height

    2.800 inches maximum

  • Inclosure Type

    fully inclosed

  • Thread Quantity Per Inch

    32 single group

  • Winding Operating Voltage

    115.00 ac volts nominal single component single primary and 120.00 ac volts nominal

  • Winding Operating Voltage

    12.00 ac volts nominal single component 1st secondary

  • Winding Operating Voltage

    82.00 ac volts nominal single component 2nd secondary

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...