CIRCUIT BREAKER

202933-610

5925-00-481-8873

5925 - Circuit Breakers

Stromberg-Carlson Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    2 threaded stud

  • Case Material

    plastic

  • Switch Contact Arrangement

    single pole,double throw

  • Mounting Surface To Terminal End Distance

    2.809 inches maximum

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    2 threaded stud

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes dc

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc

  • Trip Release Method

    magnetic

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    reset

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.138 inches

  • Switch Location And Position Designation

    internal at each pole

  • Thread Series Designator

    unc

  • Body Length

    2.515 inches maximum

  • Auxiliary Switch Function And Quantity

    1 control

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct and 70.000 maximum at 200 pct

  • Switch Current Rating And Type In Amps

    5.0 ac and 1.0 dc

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Body Width

    0.710 inches minimum and 0.760 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.939 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.061 inches nominal

  • Boss Height

    0.100 inches minimum and 0.165 inches maximum

  • Circuit Protection Type

    overcurrent

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Position Designation

    at each pole

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...