JA2-Z21-3

Circuit Breakers

CIRCUIT BREAKER

JA2-Z21-3

5925-00-482-5779

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Characteristic

    time delay all locations

  • Switch Location And Position Designation

    internal at pole two

  • Storage Type

    general purpose warehouse

  • Mounting Surface To Terminal End Distance

    2.093 inches nominal

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 28.0 dc

  • Reset Method

    manual

  • Actuator Position Designation

    at each pole

  • Thread Series Designator

    unc

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.660 inches nominal

  • Pole Quantity

    2

  • Circuit Protection Type

    overcurrent all locations

  • Special Handling Feature

    magnetic

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Switch Terminal Type

    tab, solder lug

  • Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Length

    1.560 inches nominal

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Switch Contact Arrangement

    single pole, double throw

  • Unpackaged Unit Weight

    5.000 ounces

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Body Style

    multipole-multiple actuator type

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Length

    1.985 inches minimum and 2.015 inches maximum

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Switch Current Rating And Type In Amps

    5.0 ac and 5.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Function

    trip-reset

  • Boss Height

    0.130 inches nominal

  • Case Material

    plastic

  • Maximum Continuous Load Current Rating Per Pole

    24.0 amperes ac all locations

  • External Actuator Linkage Arrangement

    one and two linked

  • Body Width

    1.500 inches nominal

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Manual Actuator Type And Quantity

    2 toggle

  • Terminal Type And Quantity

    4 tab, solder lug

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Arc Quenching Method

    magnetic blowout

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    230.0 ac all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct all locations and 1.500 maximum at 200 pct all locations

  • Nominal Thread Size

    0.138 inches

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...