AP12-77-15

Circuit Breakers

CIRCUIT BREAKER

AP12-77-15

5925-00-484-4540

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Iii Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Iii Storage Type

    general purpose warehouse

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Frequency In Hertz

    400.0 all locations

  • Test Data Document

    80249-840069 drawing

  • Thread Series Designator

    unef

  • Terminal Type And Quantity

    4 wire hook

  • Body Style

    1b multipole-single actuator type

  • Bushing Length

    0.380 inches maximum

  • Body Length

    1.562 inches maximum

  • Body Width

    1.281 inches maximum

  • Pole Quantity

    2

  • Iii Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac and 3.0 amperes dc all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    300.0 ac and 500.0 dc all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations

  • Trip Release Characteristic

    time delay all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    between pole one and two

  • Nominal Thread Size

    0.375 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.055 minimum at 200 pct and 0.950 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shockproof and vibrationproof

  • Iii Unpackaged Unit Weight

    3.600 ounces

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...