HFB3020
Circuit Breakers
CIRCUIT BREAKER
HFB3020
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Unthreaded Mounting Hole Diameter
0.180 inches minimum and 0.200 inches maximum
-
Manual Actuator Type And Quantity
1 toggle
-
Frequency In Hertz
60.0 all locations
-
Terminal Type And Quantity
6 compression
-
Main Contact Tripping Mechanism Type
trip free
-
Mounting Facility Type And Quantity
4 unthreaded hole
-
Trip Delay Time In Seconds Per Rated Continuous Current
30.000 minimum at 200 pct all locations and 70.000 maximum at 200 pct all locations
-
Body Height
3.370 inches minimum and 3.390 inches maximum
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
18000.0 ac all locations
-
Auxiliary Switch Function And Quantity
1 alarm
-
Switch Voltage Rating And Type In Volts
240.0 ac
-
Body Length
5.990 inches minimum and 6.010 inches maximum
-
Body Width
4.120 inches minimum and 4.140 inches maximum
-
Boss Height
0.110 inches minimum and 0.130 inches maximum
-
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations
-
Case Material
plastic
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.370 inches minimum and 1.390 inches maximum
-
Switch Terminal Type
tab, solder lug
-
Special Handling Feature
magnetic
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Switch Current Rating And Type In Amps
5.0 ac
-
Reset Method
manual
-
Switch Location And Position Designation
internal at pole three
-
Center To Center Distance Between Terminals Parallel To Width
1.370 inches minimum and 1.390 inches maximum
-
Storage Type
general purpose warehouse
-
Trip Release Ambient Temp Rating
40.0 deg celsius nominal all locations
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
3.449 inches minimum and 3.469 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
5.115 inches minimum and 5.135 inches maximum
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Trip Release Method
thermal-magnetic all locations
-
Actuator Position Designation
at pole two
-
Inclosure Protection Type For Which Designed
fungus resistant
-
Switch Contact Arrangement
single pole, double throw
-
Body Style
multipole-single actuator type