APL-1-1R0-43-302

Circuit Breakers

CIRCUIT BREAKER

APL-1-1R0-43-302

5925-00-488-2738

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Specification/Standard Data

    81349-mil-c-55629/2 government specification

  • Thread Series Designator

    unc

  • Frequency In Hertz

    400.0

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Switch Current Rating And Type In Amps

    10.0 ac and 2.0 dc

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant

  • Trip Delay Time In Seconds Per Rated Continuous Current

    9.500 minimum at 200 pct and 150.000 maximum at 200 pct single location

  • Switch Location And Position Designation

    internal at pole one

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip single location

  • Actuator Function

    trip-reset

  • Reset Method

    manual

  • Trip Release Characteristic

    time delay single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Mounting Surface To Terminal End Distance

    2.800 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Body Length

    2.510 inches maximum

  • Thread Pitch Diameters

    +0.1177/+0.1214 inches

  • Terminal Type And Quantity

    2 threaded stud

  • Test Data Document

    81349-mil-c-55629 specification

  • Switch Terminal Type

    tab, solder lug

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Actuator Position Designation

    at pole one

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0

  • Trip Release Method

    magnetic single location

  • Circuit Protection Type

    overcurrent single location

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac single location

  • Thread Quantity Per Inch

    32

  • Arc Quenching Method

    magnetic blowout

  • Pole Quantity

    1

  • Boss Height

    0.109 inches minimum and 0.171 inches maximum

  • Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.046 inches minimum and 2.078 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.660 inches minimum and 1.960 inches maximum

  • Case Material

    plastic

  • Body Width

    0.730 inches minimum and 0.780 inches maximum

  • Body Style

    12a single pole type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...