0N047223-1

Circuit Breakers

CIRCUIT BREAKER

0N047223-1

5925-00-488-7421

5925 - Circuit Breakers

National Security Agency

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Body Width

    0.531 inches minimum and 0.593 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Body Length

    0.719 inches minimum and 0.781 inches maximum

  • Terminal Type And Quantity

    2 tab w/screw

  • Trip Delay Time In Seconds Per Rated Continuous Current

    4.000 minimum at 200 pct single location and 16.000 maximum at 200 pct single location

  • Mounting Surface To Terminal End Distance

    1.281 inches minimum and 1.343 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.469 inches minimum and 0.531 inches maximum

  • Inclosure Protection Type For Which Designed

    moisture resistant and fungus resistant

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.438 inches

  • Reset Method

    manual

  • Trip Release Ambient Temp Rating

    25.0 deg celsius maximum single location

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Actuator Position Designation

    at pole one

  • Manual Actuator Type And Quantity

    1 push-pull

  • Pole Quantity

    1

  • Internal Trip Release Configuration

    series trip single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 28.0 dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2500.0 ac single location and 6000.0 dc single location

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Unpackaged Unit Weight

    0.057 pounds

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac single location and 2.0 amperes dc single location

  • Bushing Length

    0.040 inches minimum and 0.055 inches maximum

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...