TF6201R01
Relays and Solenoids
RELAY,ELECTROMAGNETIC
TF6201R01
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Test Data Document
81349-mil-r-5757 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Fragility Factor
moderately rugged
-
Main Contact Load Current Rating At Maximum Rated Voltage
1.0 amperes dc resistive load
-
Storage Type
general purpose warehouse
-
Nonpile-Up Main Contact Arrangement
2 pole, double throw, one position momentary
-
Environmental Protection
hermetic
-
Overall Diameter
0.370 inches maximum
-
Overall Length
0.375 inches maximum
-
Arc Quenching Method
air
-
Winding Quantity
1
-
Main Contact Load Current Rating At Maximum Rated Voltage
100.0 milliamperes dc lamp load
-
Specification/Standard Data
81349-mil-r-5757/70 government specification
-
Mounting Facility Type And Quantity
1 terminal single mounting facility
-
Case Material
metal
-
Time Delay
0.0025 seconds maximum fixed operate time
-
Operating Voltage Rating And Type At Specified Temp
26.0 volts dc 25 deg celsius single winding
-
Purpose For Which Designed
general
-
Terminal Type And Quantity
8 wire lead all functions
-
Coil Quantity
1
-
Main Contact Maximum Voltage Rating In Volts
28.0 dc
-
Nominal Operating Current Rating And Type
4.2 milliamperes dc single winding
-
Duty Type
continuous
-
Winding Dc Resistance Rating
2.9 kilohms minimum single winding and 3.6 kilohms maximum single winding
-
~1
data on certain environmental and performance