MIL-C-39019/4
Circuit Breakers
CIRCUIT BREAKER
MIL-C-39019/4
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
~1
data on certain environmental and performanc
-
Test Data Document
81349-mil-c-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac all locations
-
Switch Terminal Type
tab, solder lug
-
Circuit Protection Type
overcurrent all locations
-
Pole Quantity
2
-
Reset Method
manual
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Storage Type
general purpose warehouse
-
Switch Location And Position Designation
internal at pole two
-
Trip Release Characteristic
time delay all locations
-
Center To Center Distance Between Terminals Parallel To Width
0.625 inches nominal
-
Actuator Function
trip-reset
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.055 minimum at 200 pct all locations and 0.950 maximum at 200 pct all locations and 0.240 maximum at 400 pct all locations
-
Mounting Surface To Terminal End Distance
1.828 inches maximum
-
Internal Trip Release Configuration
series trip all locations
-
Nominal Thread Size
0.375 inches
-
Thread Quantity Per Inch
32
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
-
Trip Release Method
magnetic all locations
-
Terminal Type And Quantity
4 wire hook
-
Inclosure Protection Type For Which Designed
fungus resistant
-
Switch Contact Arrangement
single pole, double throw
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations
-
Bushing Length
0.380 inches maximum
-
External Actuator Linkage Arrangement
one and two linked
-
Body Width
1.281 inches maximum
-
Specification/Standard Data
81349-mil-c-39019/4 government specification
-
Auxiliary Switch Function And Quantity
1 alarm
-
Switch Voltage Rating And Type In Volts
120.0 ac and 50.0 dc
-
Thread Series Designator
unef
-
Frequency In Hertz
400.0 all locations
-
Center To Center Distance Between Terminals Parallel To Length
0.906 inches maximum
-
Body Length
1.562 inches maximum
-
Switch Current Rating And Type In Amps
0.5 ac and 0.5 dc
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
-
Main Contact Tripping Mechanism Type
trip free
-
Actuator Position Designation
between pole one and two
-
Manual Actuator Type And Quantity
1 toggle
-
Case Material
metal
-
Body Style
multipole-single actuator type