B13B040

Circuit Breakers

CIRCUIT BREAKER

B13B040

5925-00-497-9659

5925 - Circuit Breakers

Siemens Energy And Automation Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    plastic

  • Manual Actuator Type And Quantity

    3 toggle

  • Boss Height

    0.173 inches minimum and 0.203 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    140.0 all locations

  • Body Height

    2.327 inches minimum and 2.515 inches maximum

  • Inclosure Protection Type For Which Designed

    fungus proof

  • Terminal Type And Quantity

    3 quick disconnect, male and 3 tab, solder lug

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Unthreaded Mounting Hole Diameter

    0.219 inches nominal

  • Special Handling Feature

    magnetic

  • Fragility Factor

    moderately rugged

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Width

    2.985 inches minimum and 3.015 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    40.0 amperes ac all locations

  • Frequency In Hertz

    60.0 all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.985 inches minimum and 1.015 inches maximum

  • Trip Release Method

    thermal-magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Mounting Facility Type And Quantity

    3 unthreaded hole

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Body Length

    3.735 inches minimum and 3.765 inches maximum

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Actuator Function

    trip-reset

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Storage Type

    general purpose warehouse

  • Trip Delay Time In Seconds Per Rated Continuous Current

    360.000 nominal at 200 pct all locations

  • Reset Method

    manual

  • Actuator Position Designation

    at each pole

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...