17-13936-1

Circuit Breakers

CIRCUIT BREAKER

17-13936-1

5925-00-498-1858

5925 - Circuit Breakers

Textron Systems Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Switch Terminal Type

    tab, solder lug

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac all locations and 1.0 amperes dc all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.850 inches nominal

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.560 inches nominal

  • Reset Method

    manual

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac all locations and 28.0 dc all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2500.0 ac all locations and 2500.0 dc all locations

  • Center To Center Distance Between Terminals Parallel To Length

    1.341 inches nominal

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Body Height

    2.765 inches maximum

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Trip Delay Time In Seconds Per Rated Continuous Current

    4.000 minimum at 200 pct all locations and 35.000 maximum at 200 pct all locations

  • Manual Actuator Type And Quantity

    1 push-pull

  • Switch Voltage Rating And Type In Volts

    130.0 ac and 28.0 dc

  • Actuator Position Designation

    at pole two

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Switch Contact Arrangement

    single pole, double throw

  • Body Style

    multipole-single actuator type

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Switch Location And Position Designation

    external at pole three

  • Main Contact Tripping Mechanism Type

    trip free

  • Switch Current Rating And Type In Amps

    7.0 ac and 4.0 dc

  • Terminal Type And Quantity

    6 screw

  • Body Length

    2.000 inches maximum

  • Body Width

    0.850 inches maximum

  • Frequency In Hertz

    400.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.841 inches nominal

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Bushing Length

    0.280 inches maximum

  • Nominal Thread Size

    0.469 inches

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Trip Release Method

    thermal all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...