7276-104-2
Circuit Breakers
CIRCUIT BREAKER
7276-104-2
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Switch Terminal Type
tab, solder lug
-
Center To Center Distance Between Terminals Parallel To Width
0.850 inches nominal
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac all locations and 2.0 amperes dc all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.560 inches nominal
-
Reset Method
manual
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac all locations and 28.0 dc all locations
-
Switch Location And Position Designation
internal at pole three
-
Thread Series Designator
uns
-
Case Material
plastic
-
Trip Release Method
thermal all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2500.0 ac all locations and 2500.0 dc all locations
-
Center To Center Distance Between Terminals Parallel To Length
1.341 inches nominal
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
145.0 all locations
-
Internal Trip Release Configuration
series trip all locations
-
Body Height
2.765 inches maximum
-
Thread Quantity Per Inch
32
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Nominal Thread Size
0.469 inches
-
Bushing Length
0.280 inches maximum
-
Auxiliary Switch Function And Quantity
1 alarm
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.841 inches nominal
-
Frequency In Hertz
400.0 all locations
-
Body Width
0.850 inches maximum
-
Body Length
2.000 inches maximum
-
Terminal Type And Quantity
6 screw
-
Switch Current Rating And Type In Amps
7.0 ac and 4.0 dc
-
Main Contact Tripping Mechanism Type
trip free
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal all locations
-
Body Style
multipole-single actuator type
-
Switch Contact Arrangement
single pole, double throw
-
Inclosure Protection Type For Which Designed
fungus resistant
-
Actuator Position Designation
at pole two
-
Switch Voltage Rating And Type In Volts
130.0 ac and 28.0 dc
-
Manual Actuator Type And Quantity
1 push-pull
-
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 minimum at 200 pct all locations and 35.000 maximum at 200 pct all locations