HE3A2A3-10-60-1

Circuit Breakers

CIRCUIT BREAKER

HE3A2A3-10-60-1

5925-00-498-3557

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    multipole-single actuator type

  • Bushing Length

    0.375 inches nominal

  • Body Width

    1.281 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Pole Quantity

    2

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac

  • Circuit Protection Type

    overcurrent

  • Trip Release Characteristic

    time delay

  • Actuator Function

    trip-reset

  • Switch Location And Position Designation

    internal at pole two

  • Switch Current Rating And Type In Amps

    1.0 ac and 0.5 dc

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 50.0 dc

  • Terminal Type And Quantity

    4 wire hook

  • Body Length

    1.562 inches maximum

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Switch Contact Arrangement

    single pole,double throw

  • Mounting Surface To Terminal End Distance

    1.700 inches maximum

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac

  • Trip Release Method

    magnetic-hydraulic

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    between pole one and two

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.375 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.900 minimum at 200 pct and 4.500 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    fungus resistant and hermetically sealed

  • Switch Terminal Type

    tab,solder lug

  • Frequency In Hertz

    60.0

  • Thread Series Designator

    unef

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...