ETN1073

Circuit Breakers

CIRCUIT BREAKER

ETN1073

5925-00-501-5051

5925 - Circuit Breakers

Spd Electrical Systems Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Specification/Standard Data

    81349-mil-c-17588 government specification

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Precious Material

    silver

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Mounting Facility Type And Quantity

    1 terminal and 1 clip

  • Inclosure Protection Type For Which Designed

    vibration resistant and shock resistant

  • Circuit Protection Type

    overcurrent single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct single location and 210.000 maximum at 200 pct single location

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal single location

  • Body Height

    2.313 inches nominal

  • Trip Release Method

    thermal-magnetic single location

  • Body Length

    3.500 inches nominal

  • Boss Height

    0.188 inches nominal

  • Trip Release Characteristic

    time delay single location

  • Test Data Document

    81349-mil-c-17588 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • ~1

    data on certain environmental and performanc

  • Case Material

    plastic

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 125.0 dc single location

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac single location and 20.0 amperes dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location and 2500.0 dc single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Body Style

    single pole type

  • Terminal Type And Quantity

    1 compression and 1 quick disconnect, female

  • Frequency In Hertz

    400.0 single location

  • Precious Material And Location

    contact surfaces silver

  • Body Width

    0.969 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...