MIL-R-6106

Relays and Solenoids

RELAY,ELECTROMAGNETIC

MIL-R-6106

5945-00-502-2874

5945 - Relays and Solenoids

Military Specifications

RELAY,ELECTROMAGNETIC

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Environmental Protection

    hermetic

  • Iii Fragility Factor

    moderately rugged

  • Winding Quantity

    1

  • Nonpile-Up Main Contact Arrangement

    1 pole, single throw, normally open, double make, momentary action

  • Operating Voltage Rating And Type At Specified Temp

    28.0 volts dc 25 deg celsius single winding

  • Main Contact Load Current Rating At Maximum Rated Voltage

    100.0 amperes dc inductive load

  • Definitive Government Spec/Std Reference

    ms25033-1

  • Manufacturers Code

    81349

  • Manufacturers Code

    96906

  • Non-Definitive Government Spec/Std Reference

    mil-prf-6106

  • Test Data Document

    81349-mil-r-6106 specification

  • Specification/Standard Data

    96906-ms25033 government standard

  • Main Contact Load Current Rating At Maximum Rated Voltage

    200.0 amperes dc resistive load

  • Main Contact Maximum Voltage Rating In Volts

    28.0 dc

  • Iii Unpackaged Unit Weight

    2.000 pounds

  • Terminal Type And Quantity

    4 threaded stud all functions

  • Overall Length

    3.640 inches maximum

  • Center To Center Distance Between Mounting Facilities Parallel To Length

    3.000 inches nominal single mounting facility

  • Overall Height

    3.906 inches maximum

  • Overall Width

    2.812 inches maximum

  • Iii Case Material

    metal

  • Unthreaded Mounting Hole Diameter

    0.312 inches nominal single mounting facility

  • Iii Purpose For Which Designed

    general

  • Coil Quantity

    1

  • Duty Type

    continuous

  • Arc Quenching Method

    air

  • Mounting Facility Type And Quantity

    2 unthreaded hole single mounting facility

  • Iii Storage Type

    general purpose warehouse

  • Iii Cubic Measure

    39.980 cubic inches

  • Mounting Facility Pattern

    in-line single mounting facility

  • Main Contact Load Current Rating At Maximum Rated Voltage

    200.0 amperes dc motor load

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.