12404

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

12404

5915-00-503-0010

5915 - Filters and Networks

Honeywell International Inc

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Operating Current Rating Per Function In Amps

    5.0 3rd radio interference

  • Overall Length

    4.100 inches nominal

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Input Terminal Identification

    an3102-145-75

  • Unthreaded Mounting Hole Diameter

    0.1975 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.360 inches minimum and 3.380 inches maximum

  • Functional Terminal Type And Quantity

    1 connector, receptacle input 1st function

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Style Designator

    rectangular terminal/terminals on opposite surfaces

  • Input Terminal Manufacturer Code

    16906

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Operating Voltage Rating And Type Per Function

    100.0 volts dc 1st radio interference 1st function

  • Functional Terminal Type And Quantity

    3 threaded stud output 2nd function

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Body Length

    2.750 inches nominal

  • Overall Height

    1.550 inches nominal

  • Maximum Voltage Drop Per Function

    0.150 volts dc 1st radio interference

  • Operating Voltage Rating And Type Per Function

    100.0 volts dc 2nd radio interference 2nd function

  • Operating Current Rating Per Function In Amps

    5.0 1st radio interference

  • Operating Voltage Rating And Type Per Function

    100.0 volts dc 3rd radio interference 3rd function

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Operating Temp Range

    -0.0/+175.0 deg fahrenheit

  • Maximum Voltage Drop Per Function

    0.150 volts dc 2nd radio interference

  • Inclosure Type

    hermetically sealed

  • Maximum Voltage Drop Per Function

    0.150 volts dc 3rd radio interference

  • Body Width

    2.630 inches nominal

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Operating Current Rating Per Function In Amps

    5.0 2nd radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...