2131644-5
Circuit Breakers
CIRCUIT BREAKER
2131644-5
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac all locations
-
Manual Actuator Type And Quantity
3 toggle
-
Case Material
plastic
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches nominal
-
Terminal Type And Quantity
6 threaded stud
-
Mounting Surface To Terminal End Distance
2.640 inches nominal
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Trip Release Characteristic
instantaneous all locations
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Boss Height
0.150 inches nominal
-
Actuator Function
trip-reset
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Internal Trip Release Configuration
series trip all locations
-
Center To Center Distance Between Terminals Parallel To Length
1.940 inches nominal
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
7.5 amperes ac all locations
-
Trip Release Method
magnetic all locations
-
Body Style
multipole-multiple actuator type
-
Mounting Facility Type And Quantity
6 threaded hole
-
Nominal Thread Size
0.138 inches
-
Body Width
2.250 inches nominal
-
Operating Voltage Type And Rating Per Pole In Volts
125.0 ac all locations
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Body Length
2.500 inches nominal
-
Frequency In Hertz
400.0 all locations