AP12R-1918-15

Circuit Breakers

CIRCUIT BREAKER

AP12R-1918-15

5925-00-506-2295

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Nonturn Device Diameter

    0.245 inches minimum and 0.255 inches maximum

  • Fragility Factor

    moderately rugged

  • Nonturn Device Length

    0.135 inches minimum and 0.145 inches maximum

  • Switch Terminal Type

    tab, solder lug

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Unpackaged Unit Weight

    5.600 ounces

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc all locations

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Nonturn Device Radius

    0.620 inches minimum and 0.630 inches maximum

  • Trip Release Method

    magnetic all locations

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Terminal Type And Quantity

    4 wire hook

  • Switch Contact Arrangement

    single pole, double throw

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Nonturn Device Location

    at 3 oclock and at 9 oclock

  • Body Style

    multipole-single actuator type

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Body Length

    1.500 inches maximum

  • Actuator Position Designation

    between pole one and two

  • Switch Current Rating And Type In Amps

    0.5 ac and 0.5 dc

  • Body Width

    1.250 inches maximum

  • Thread Series Designator

    unef

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 50.0 dc

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.070 minimum at 200 pct all locations and 0.700 maximum at 200 pct all locations

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes dc first location

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes dc second location

  • Inclosure Protection Type For Which Designed

    shockproof and hermetically sealed and vibrationproof

  • Bushing Length

    0.380 inches maximum

  • Switch Location And Position Designation

    internal at pole one

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Arc Quenching Method

    magnetic blowout

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...