AP112-1918-7
Circuit Breakers
CIRCUIT BREAKER
AP112-1918-7
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Circuit Protection Type
overcurrent all locations
-
Trip Release Method
magnetic all locations
-
Body Style
1b multipole-single actuator type
-
Bushing Length
0.380 inches maximum
-
Body Length
1.500 inches maximum
-
Body Width
1.875 inches maximum
-
Case Material
metal
-
Nonturn Device Location
at 3 oclock and at 9 oclock
-
Nonturn Device Radius
0.625 inches nominal
-
Nonturn Device Diameter
0.250 inches nominal
-
Arc Quenching Method
magnetic blowout
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Storage Type
general purpose warehouse
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac first location
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes dc second location
-
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac first location
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc second location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
10000.0 ac first location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc second location
-
Reset Method
manual
-
Actuator Function
trip-reset
-
Internal Trip Release Configuration
series trip all locations
-
Nominal Thread Size
0.375 inches
-
Inclosure Protection Type For Which Designed
hermetically sealed
-
Terminal Type And Quantity
6 wire hook
-
Thread Pitch Diameters
+0.3503/+0.3537 inches
-
Center To Center Distance Between Terminals Parallel To Length
0.870 inches minimum and 0.880 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
0.620 inches minimum and 0.630 inches maximum
-
Nonturn Device Length
0.140 inches nominal
-
Fragility Factor
moderately rugged
-
Mounting Surface To Terminal End Distance
1.780 inches maximum
-
Pole Quantity
3
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes dc third location
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc third location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc third location
-
Trip Release Characteristic
time delay all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Position Designation
at pole two
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.055 minimum at 200 pct and 0.950 maximum at 200 pct all locations
-
Frequency In Hertz
60.0
-
Thread Series Designator
unef