Technical Characteristics

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.000 minimum at 200 pct all locations and 100.000 maximum at 200 pct all locations

  • Trip Release Ambient Temp Rating

    40.0 deg celsius maximum all locations

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 all locations

  • Body Length

    6.000 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.172 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.500 inches nominal

  • Case Material

    plastic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Width

    1.500 inches nominal

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Body Width

    4.469 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    5.125 inches nominal

  • Trip Release Method

    thermal-magnetic all locations

  • Body Height

    3.000 inches nominal

  • Actuator Position Designation

    at pole two

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Body Style

    multipole-single actuator type

  • Center To Center Distance Between Terminals Parallel To Length

    5.125 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac all locations

  • Boss Height

    0.156 inches nominal

  • Frequency In Hertz

    60.0 all locations

  • Terminal Type And Quantity

    6 compression

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...