EH2B020

Circuit Breakers

CIRCUIT BREAKER

EH2B020

5925-00-506-6683

5925 - Circuit Breakers

Siemens-Allis Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.000 inches nominal

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Width

    1.500 inches nominal

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Case Material

    plastic

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac all locations and 250.0 dc all locations

  • Bushing Length

    0.219 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    28.000 minimum at 200 pct all locations and 65.000 maximum at 200 pct all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    14000.0 ac all locations and 10000.0 dc all locations

  • Body Length

    6.000 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    4.984 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Unthreaded Mounting Hole Diameter

    0.164 inches nominal

  • Frequency In Hertz

    60.0 all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Body Width

    3.000 inches nominal

  • Terminal Type And Quantity

    4 compression

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Trip Release Method

    thermal-magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Body Style

    multipole-multiple actuator type

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac all locations and 20.0 amperes dc all locations

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Mounting Surface To Terminal End Distance

    3.594 inches nominal

  • Actuator Function

    trip-reset

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...