262-5000-004
Relays and Solenoids
RELAY,ELECTROMAGNETIC
262-5000-004
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.000 inches nominal single mounting facility
-
Overall Height
3.250 inches maximum
-
Winding Quantity
1
-
Overall Length
2.500 inches maximum
-
Environmental Protection
shock resistant and vibration resistant
-
Unthreaded Mounting Hole Diameter
0.166 inches minimum single mounting facility and 0.181 inches maximum single mounting facility
-
Time Delay
0.015 seconds maximum fixed release time
-
Main Contact Maximum Voltage Rating In Volts
200.0 ac and 28.0 dc
-
Coil Quantity
1
-
Terminal Type And Quantity
11 threaded stud all functions
-
Time Delay
0.05 seconds maximum fixed operate time
-
Overall Width
2.440 inches maximum
-
Nonpile-Up Main Contact Arrangement
3 pole, double throw, one position momentary
-
Main Contact Load Current Rating At Maximum Rated Voltage
30.0 amperes ac motor load and 5.0 amperes dc motor load
-
Duty Type
continuous
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.000 inches nominal single mounting facility
-
Main Contact Load Current Rating At Maximum Rated Voltage
50.0 amperes ac resistive load and 10.0 amperes dc resistive load
-
Operating Voltage Rating And Type At Specified Temp
28.0 volts teardrop, two holes type 4f single winding
-
Mounting Facility Type And Quantity
4 unthreaded hole single mounting facility
-
Mounting Facility Pattern
rectangular single mounting facility
-
Main Contact Load Current Rating At Maximum Rated Voltage
15.0 amperes ac lamp load and 5.0 amperes dc lamp load