JA1-A3-20-3

Circuit Breakers

CIRCUIT BREAKER

JA1-A3-20-3

5925-00-507-4826

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Boss Height

    0.125 inches minimum and 0.135 inches maximum

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac single location

  • Terminal Type And Quantity

    2 tab, solder lug

  • Body Style

    single pole type

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.655 inches minimum and 1.665 inches maximum

  • Trip Release Method

    magnetic-hydraulic single location

  • Frequency In Hertz

    60.0 single location

  • Unpackaged Unit Weight

    2.500 ounces

  • Mounting Surface To Terminal End Distance

    1.875 inches minimum and 1.885 inches maximum

  • Case Material

    plastic

  • Pole Quantity

    1

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Fragility Factor

    moderately rugged

  • Body Width

    0.745 inches minimum and 0.755 inches maximum

  • Thread Series Designator

    unc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Length

    1.555 inches minimum and 1.565 inches maximum

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.190 minimum at 200 pct single location and 1.900 maximum at 200 pct single location

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Body Length

    1.985 inches minimum and 2.015 inches maximum

  • Circuit Protection Type

    overcurrent single location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...