GC885Y5
Circuit Breakers
CIRCUIT BREAKER
GC885Y5
Northrop Grumman Systems Corporation
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac all locations and 5.0 amperes dc all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
6000.0 ac all locations and 35000.0 dc all locations
-
Bushing Length
0.250 inches nominal
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Operating Voltage Type And Rating Per Pole In Volts
200.0 ac all locations and 28.0 dc all locations
-
Mounting Surface To Terminal End Distance
1.703 inches nominal
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Center To Center Distance Between Terminals Parallel To Length
0.701 inches nominal
-
Main Contact Tripping Mechanism Type
trip free
-
Terminal Type And Quantity
6 screw
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 400 pct all locations and 10.000 maximum at 400 pct all locations
-
Frequency In Hertz
400.0 all locations
-
Manual Actuator Type And Quantity
3 push-pull
-
Body Length
1.218 inches nominal
-
Nominal Thread Size
0.469 inches
-
Thread Series Designator
uns
-
Case Material
plastic
-
Trip Release Method
thermal all locations
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Internal Trip Release Configuration
series trip all locations
-
Thread Quantity Per Inch
32
-
Center To Center Distance Between Terminals Parallel To Width
0.875 inches nominal
-
Body Style
multipole-multiple actuator type
-
Inclosure Protection Type For Which Designed
fungus resistant
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal all locations
-
Mounting Facility Type And Quantity
3 threaded bushing
-
Body Width
2.437 inches nominal