UPG1-1-6-1-102-01

Circuit Breakers

CIRCUIT BREAKER

UPG1-1-6-1-102-01

5925-00-511-4942

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Series Designator

    unc

  • Body Width

    0.750 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Pole Quantity

    1

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    1000.0 single location

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.700 minimum at 125 pct and 12.000 maximum at 125 pct and 0.350 minimum at 150 pct and 4.000 maximum at 150 pct and 0.130 minimum at 200 pct and 1.300 maximum at 200 pct and 0.030 minimum at 400 pct and 0.200 maximum at 400 pct and 0.003 minimum at 1000

  • Inclosure Protection Type For Which Designed

    moisture resistant and vibrationproof and salt spray proof

  • Frequency In Hertz

    60.0 single location

  • Manufacturers Code

    81541

  • Ultimate Trip Time Per Pole In Seconds

    0.003 minimum and 0.040 maximum single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole one

  • ~1

    pct and 0.040 maximum at 1000 pct and 0.008 minimum at 600 pct and 0.130 maximum at 600 pct and 0.003 minimum at 800 pct and 0.070 maximum at 800 pct single location

  • Special Features

    handle color with on-off markings black with white markings

  • Design Control Reference

    upg1-1-6-1-102-01

  • Terminal Type And Quantity

    2 tab, solder lug

  • Body Style

    4a single pole type

  • Body Length

    2.000 inches nominal

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.660 inches nominal

  • Mounting Surface To Terminal End Distance

    2.000 inches maximum

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac single location

  • Operating Voltage Type And Rating Per Pole In Volts

    277.0 ac single location

  • Circuit Protection Type

    overcurrent single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...