ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Nonturn Device Diameter

    0.245 inches minimum and 0.255 inches maximum

  • Fragility Factor

    moderately rugged

  • Nonturn Device Length

    0.135 inches minimum and 0.145 inches maximum

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac first location

  • Reset Method

    manual

  • Frequency In Hertz

    400.0 first location

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Nonturn Device Radius

    0.620 inches minimum and 0.630 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac first location

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.375 inches

  • Bushing Length

    0.380 inches maximum

  • Terminal Type And Quantity

    6 wire hook

  • Body Width

    1.875 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc third location

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes dc third location

  • Thread Pitch Diameters

    +0.3503/+0.3537 inches

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes dc second location

  • Actuator Function

    trip-reset

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Unpackaged Unit Weight

    5.400 ounces

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.070 minimum at 200 pct all locations and 0.700 maximum at 200 pct all locations

  • Thread Series Designator

    unef

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc third location

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc second location

  • Arc Quenching Method

    magnetic blowout

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Position Designation

    between pole one and two

  • Body Length

    1.500 inches maximum

  • Manual Actuator Type And Quantity

    1 toggle

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc second location

  • Case Material

    metal

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shockproof and vibrationproof

  • Body Style

    multipole-single actuator type

  • Nonturn Device Location

    at 3 oclock and at 9 oclock

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Trip Release Method

    magnetic all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac first location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...