2131850-14

Circuit Breakers

CIRCUIT BREAKER

2131850-14

5925-00-512-9026

5925 - Circuit Breakers

Honeywell Intl Inc Defense Avionics

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    1b multipole-single actuator type

  • Body Length

    1.500 inches maximum

  • Body Width

    1.250 inches maximum

  • Nonturn Device Radius

    0.620 inches minimum and 0.630 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac first location

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes dc second location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc second location

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Characteristic

    time delay all locations

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    between pole one and two

  • Nominal Thread Size

    0.375 inches

  • Frequency In Hertz

    400.0

  • Bushing Length

    0.380 inches maximum

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Nonturn Device Location

    at 3 oclock and at 9 oclock

  • Nonturn Device Length

    0.135 inches minimum and 0.145 inches maximum

  • Nonturn Device Diameter

    0.245 inches minimum and 0.255 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Pole Quantity

    2

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac first location

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc second location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac first location

  • Trip Release Method

    magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Internal Trip Release Configuration

    series trip all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.070 minimum at 200 pct and 0.700 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shockproof and vibrationproof

  • Unpackaged Unit Weight

    3.600 ounces

  • Thread Series Designator

    unef

  • Terminal Type And Quantity

    4 wire hook

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...