PAM12MG6-10-250-60

Circuit Breakers

CIRCUIT BREAKER

PAM12MG6-10-250-60

5925-00-513-1993

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Series Designator

    unc

  • Unpackaged Unit Weight

    4.250 ounces

  • Frequency In Hertz

    60.0 single location

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac single location

  • Thread Quantity Per Inch

    32

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Arc Quenching Method

    magnetic blowout

  • Mounting Surface To Terminal End Distance

    2.549 inches minimum and 2.673 inches maximum

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Case Material

    plastic

  • Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Terminal Type And Quantity

    2 threaded stud

  • Actuator Position Designation

    at pole one

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Characteristic

    instantaneous single location

  • Circuit Protection Type

    overcurrent single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Pole Quantity

    1

  • Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

  • Body Style

    12a single pole type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...