Technical Characteristics

  • Iii Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    2.000 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.406 inches nominal

  • Case Material

    plastic

  • Body Width

    1.880 inches nominal

  • Body Style

    17a single pole type

  • Non-Definitive Government Spec/Std Reference

    aa55571/07

  • Manufacturers Code

    58536

  • Definitive Government Spec/Std Reference

    aa55571/07-003

  • Inclosure Protection Type For Which Designed

    vibration resistant and

  • Inclosure Protection Type For Which Designed

    shock resistant and

  • Inclosure Protection Type For Which Designed

    salt spray proof and

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Trip Delay Time In Seconds Per Rated Continuous Current

    50.000 maximum at 200 pct single location

  • Internal Trip Release Configuration

    series trip single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    575.0 dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc single location

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Pole Quantity

    1

  • Unthreaded Mounting Hole Diameter

    0.225 inches maximum

  • Unthreaded Mounting Hole Diameter

    0.195 inches minimum and

  • Center To Center Distance Between Terminals Parallel To Length

    1.060 inches nominal

  • Overall Length

    3.160 inches nominal

  • Iii Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    45.0 amperes dc single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Trip Release Characteristic

    time delay single location

  • Reset Method

    automatic

  • Trip Delay Time In Seconds Per Rated Continuous Current

    8.000 minimum at 200 pct and

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Terminal Type And Quantity

    2 threaded stud

  • Specification/Standard Data

    58536-aa55571/07-003 government specification

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...