TW63700
Coils and Transformers
TRANSFORMER,POWER
TW63700
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Thread Series Designator
unc single group
-
Inclosure Type
hermetically sealed
-
Input-Output Phase Relationship
single phase to single phase single component
-
Frequency Rating
400.0 hertz nominal single component
-
Reliability Indicator
not established
-
Winding Operating Current
100.0 milliamperes ac maximum single component 3rd secondary
-
Body Outside Diameter
1.380 inches nominal
-
Winding Operating Voltage
35.00 ac volts maximum single component all secondary
-
Winding Operating Voltage
115.00 ac volts maximum single component single primary
-
Winding Function And Quantity
1 primary single component and 2 secondary single component
-
Thread Quantity Per Inch
32 single group
-
Mounting Method
threaded stud single group
-
Distance Between Mounting Facility Centers
1.000 inches nominal single mounting facility single center group
-
Nominal Thread Size
0.164 inches single group
-
Mounting Facility Quantity
2 single group
-
Body Length
1.120 inches nominal
-
Terminal Type And Quantity
6 turret