5165626

Coils and Transformers

TRANSFORMER,POWER

5165626

5950-00-532-0900

5950 - Coils and Transformers

Naval Sea Systems Command

TRANSFORMER,POWER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Overall Height

    1.125 inches minimum and 1.155 inches maximum

  • Mounting Hole Diameter

    0.111 inches minimum single group and 0.121 inches maximum single group

  • Input-Output Phase Relationship

    single phase to single phase single component

  • Winding Operating Voltage

    115.00 ac volts nominal single component single primary

  • Unpackaged Unit Weight (Non-Core)

    0.060 pounds

  • Overall Width

    0.765 inches minimum and 0.795 inches maximum

  • Criticality Code Justification

    feat

  • Mounting Facility Quantity

    2 single group

  • End Item Identification

    ticonderoga class cg (47); oliver perry class ffg; spruance class dd (963); virginia class cgn (41); kidd class ddg; aircraft, viking s-3b

  • Special Features

    weapon system essential

  • Center To Center Distance Between Mounting Facilities Parallel To Length

    0.665 inches minimum single mounting facility single center group and 0.695 inches maximum single mounting facility single center group

  • Winding Operating Voltage

    28.00 ac volts nominal single component single secondary

  • Terminal Type And Quantity

    5 turret

  • Winding Tap Location (Non-Core)

    err-070

  • Winding Operating Current

    71.0 milliamperes ac nominal single component single secondary

  • Inclosure Type

    fully inclosed

  • Winding Function And Quantity

    1 primary single component and 1 secondary single component

  • Center To Center Distance Between Mounting Facilities Parallel To Width

    0.535 inches minimum single mounting facility single center group and 0.565 inches maximum single mounting facility single center group

  • Mounting Method

    unthreaded hole single group

  • Overall Length

    0.855 inches minimum and 0.885 inches maximum

  • Maximum Operating Temp

    85.0 deg celsius

  • Reliability Indicator

    not established

  • Frequency Rating

    400.0 hertz nominal single component

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...