32378

Switches

SWITCH,PRESSURE

32378

5930-00-538-3406

5930 - Switches

Ranco Management Corp

SWITCH,PRESSURE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Nonpile-Up Contact Arrangement

    2 pole, single throw, normally open, momentary action

  • Terminal Type

    tab w/screw

  • Longest Vertical Distance Between Mounting Centers

    1.812 inches nominal

  • Contact Voltage Rating In Volts

    230.0 ac at sea level first voltage

  • Contact Voltage Rating In Volts

    115.0 dc at sea level fourth voltage

  • Unthreaded Mounting Hole Diameter

    0.406 inches nominal

  • Contact Load Current Rating

    16.0 amperes resistive load second voltage

  • Special Features

    shortest vertical distance between mtg centers 0.531 in.

  • Contact Adjustment Range

    +100.00/+250.00 actuation point pounds per square inch and +85.00/+225.00 deactuation point pounds per square inch

  • Thread Series Designator

    unc all pressure connection

  • Longest Horizontal Distance Between Mounting Centers

    4.500 inches nominal

  • Overall Width

    1.906 inches maximum

  • Pressure Connector Type

    flared, threaded external all connections

  • Overall Length

    5.312 inches maximum

  • Thread Quantity Per Inch

    20 all pressure connection

  • Mounting Facility Pattern

    obtuse triangle

  • Contact Adjustment Type

    external deactuation point knob with scale and external actuation point knob with scale

  • Contact Adjustability

    deactuation point adjustable, preset and actuation point adjustable, preset

  • Body Height

    2.656 inches maximum

  • Mounting Method

    flush and unthreaded hole

  • Style Designator

    rectangular

  • Media For Which Designed

    gas or liquid

  • Contact Load Current Rating

    10.0 amperes resistive load first voltage

  • Contact Voltage Rating In Volts

    115.0 ac at sea level second voltage

  • Nominal Thread Size

    0.4375 inches single pressure connection

  • Contact Voltage Rating In Volts

    230.0 dc at sea level third voltage

  • Overall Height

    4.656 inches maximum

  • Pressure Switch Type

    gage

  • Contact Load Current Rating

    4.6 amperes resistive load fourth voltage

  • Contact Stimulus Rating

    15.00 differential point minimum pounds per square inch and 25.00 differential point maximum pounds per square inch

  • Contact Load Current Rating

    4.3 amperes resistive load third voltage

  • Contact Action Stimulus

    increase

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...