AMB-400
Resistors
RESISTOR,VARIABLE,WIRE WOUND,PRECISION
AMB-400
RESISTOR,VARIABLE,WIRE WOUND,PRECISION
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Style
5b cylindrical servo mounted
-
Overall Length
2.344 inches maximum
-
Undercut Width
0.0620 inches nominal
-
Shaft Length
0.308 inches nominal
-
Body Length
2.031 inches nominal
-
Mounting Lip Depth
0.0620 inches nominal
-
Shaft Bearing Type
ball
-
Actuator Type
single shaft
-
Effective Electrical Rotation In Deg Angular Rotation
351.3 nominal
-
Maximum Starting Torque
2.50 inch-ounces (ounce-inches)
-
Lateral Runout
0.002 inches
-
Terminal Location
radially positioned over more than half the circumference
-
Mounting Method
clamp ring
-
Electrical Resistance Per Section
20.000 kilohms 1st section
-
Electrical Resistance Per Section
40.000 kilohms 3rd section
-
Rotary Actuator Travel In Angular Deg
360.0 nominal
-
Function Conformity Tolerance Per Section
-0.50 to 0.50 all sections
-
Power Dissipation Rating Per Section In Watts
4.0 free air all sections
-
Function Conformity Per Section
all sections independent linearity
-
Tap Location Tolerance Per Section
-1.5 to 1.5 deg angular rotation all sections
-
Resistance Tolerance Per Section In Percent
-5.0 to 5.0 all sections
-
Actuator Travel Control Feature
continuous motion
-
Ambient Temp In Deg Celsius Per Section At Full Rated Power
25.0 all sections
-
Terminal Type And Quantity
12 solder stud
-
Section Quantity
3
-
Reliability Indicator
not established
-
Pilot Diameter
1.7500 inches nominal
-
Pilot Length
0.0620 inches nominal
-
Undercut Diameter
1.875 inches nominal
-
Body Diameter
2.000 inches nominal
-
Shaft Diameter
0.250 inches nominal
-
Overall Diameter
2.188 inches nominal
-
Mounting Lip Diameter
2.0000 inches nominal
-
Shaft Style
1c round
-
Shaft End Play
0.00150 inches
-
Shaft Runout
0.001 inches
-
Pilot Diameter Runout
0.00300 inches
-
Shaft Radial Play
0.001 inches
-
Electrical Resistance Per Section
40.000 kilohms 2nd section
-
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation
130.0 2nd section
-
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation
42.0 1st section
-
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation
42.0 3rd section
-
Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power
150.0 all sections
-
Fixed Tap Quantity Per Section
1 all sections
-
Function Characteristic Per Section
all sections linear