AM13MG6-0.5-117-60-4

Circuit Breakers

CIRCUIT BREAKER

AM13MG6-0.5-117-60-4

5925-00-542-8895

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Frequency In Hertz

    60.0 single location

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Terminal Type And Quantity

    2 threaded stud

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant and explosion resistant

  • Thread Series Designator

    unc

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.812 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Operating Voltage Type And Rating Per Pole In Volts

    117.0 ac single location

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Mounting Surface To Terminal End Distance

    2.611 inches nominal

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Maximum Continuous Load Current Rating Per Pole

    500.0 milliamperes ac single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Body Length

    2.500 inches nominal

  • Body Style

    single pole type

  • Trip Release Method

    magnetic-hydraulic single location

  • Actuator Position Designation

    at pole one

  • Unpackaged Unit Weight

    4.250 ounces

  • Storage Type

    general purpose warehouse

  • Body Width

    0.750 inches nominal

  • Actuator Function

    trip-reset

  • Trip Delay Time In Seconds Per Rated Continuous Current

    4.000 minimum at 200 pct single location and 10.000 maximum at 200 pct single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...