Technical Characteristics
-
Bulb Diameter
0.188 inches nominal
-
Temp Sensing Element Type
capillary tube-bulb
-
Contact Adjustability
deactuation point adjustable and actuation point adjustable
-
Thread Quantity Per Inch
32 all threaded hole
-
Overall Length
3.062 inches nominal
-
Nonpile-Up Contact Arrangement
2 pole, single throw, normally open, momentary action
-
Terminal Type
tab w/screw
-
Contact Load Current Rating
15.0 amperes resistive load first voltage
-
Contact Load Current Rating
10.0 amperes resistive load second voltage
-
Contact Adjustment Range
+200.00/+550.00 actuation point degrees fahrenheit and +200.00/+550.00 deactuation point degrees fahrenheit
-
Contact Adjustment Type
external deactuation point knob and external actuation point knob
-
Capillary Tube Length
24.000 inches nominal
-
Bulb Length
13.000 inches nominal
-
Thread Series Designator
unc all threaded hole
-
Contact Voltage Rating In Volts
230.0 dc at sea level second voltage
-
Style Designator
rectangular
-
Nominal Thread Size
0.138 inches all threaded hole
-
Media For Which Designed
gas or liquid
-
Longest Horizontal Distance Between Mounting Centers
1.750 inches nominal
-
Overall Height
3.906 inches nominal
-
Mounting Method
bracket and threaded hole
-
Mounting Facility Pattern
two position in-line
-
Contact Action Stimulus
increase
-
Contact Voltage Rating In Volts
125.0 dc at sea level first voltage